OM-CP-AVS150-5-CERT采集 美國omega
Autoclave Validation System
OM-CP-AVS150-CERT and OM-CP-AVS150-5-CERT
5年保修 新產品! CE
Autoclave Validation System
OM-CP-AVS150-CERT and OM-CP-AVS150-5-CERT:Autoclave Validation System
OM-CP-AVS150-CERT
Enables compliance with
FDA 21 CFR Part 11
Software Calculates Thermal
Resistance in F0
NIST Traceable Calibration Included
Stand Alone, Complete System
No Thermocouple Wires
Digital Calibration Through Software
The OM-CP-AVS150 is a complete system used to perform autoclave validations. The OM-CP-AVS150 consists of a NIST traceable OM-CP-HITEMP-150 data logger, an IP68 extended range thermal shield, an OM-CP-IFC200 USB cable package and FDA 21 CFR part 11 secure software. For larger size autoclaves or mapping projects, the OM-CP-AVS150-5, includes five OM-CP-HITEMP-150’s and five thermal shields. The OM-CP-HITEMP-150 is compley submersible and can measure temperatures up to 150°C (302°F). The 51 mm (2") rigid probe provides a fast response time and can record readings as fast as once per second. The OM-CP-HITEMP-150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (482°F) (time dependent).
The secure software provides data in graphical and tabular form, and provides a summary and statistical report of the data. The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up to auditors.
This device can be started and stopped directly from a computer and their compact design allows them to fit almost anywhere. Data retrieval is simple. Plug the device into an available USB port and our easy-to-use software does the rest. The software converts a PC into a real-time strip chart recorder. Data can be printed in graphical and tabular format or exported to a text or Microsoft Excel file.
規格:
OM-CP-HITEMP-150
DATA LOGGER
Temperature Sensor: 100Ω platinum RTD
Temperature Range: -40 to 150oC (-40 to 212oF)
Temperature Resolution: 0.05oC
Calibrated Accuracy: ±0.5oC
Start Modes: Software Programmable
Start now
Delay start
Memory: 32,767 readings
Reading Rate: One second up to 12 hours
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.9V high-temperature lithium battery (included); factory replaceable only
Battery Life: 1 year typical (1 minute reading rate @25oC)
Data Format: Date and time stamped oC, oF, K, oR
Time Accuracy: ±1 minute/month at 20oC (RS232 cable not in use)
Computer Interface: PC serial or USB (interface cable required); 2400 baud
Software: Windows XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 150oC (-40 to 302°F), 0 to 100% RH
Dimensions:
Body: 28 x 45 mm dia. (1.1 x 1.75")
Probe: 50 x 5 mm dia. (2.0 x 3/16")
Weight:
OM-CP-HITEMP-150: 225 g (8 oz)
OM-CP-AVS150: 1.72 kg (3.8 lb)
OM-CP-AVS150-5: 3.81 kg (8.4 lb)
Material: 316 stainless steel
Specifications
(Thermal Shield)
Operating Envionment: -200 to 250°C (-328 to 482°F) time limited, see table on PDF
IP Rating: IP68
Dimensions: 53.3 H x 66 mm dia (2.1 X 2.6")
Weight: 0.3 kg (0.65 lb)
Material: Teflon
產品型號 產品描述
OM-CP-AVS150-CERT
Includes (1) OM-CP-HITEMP-150 data logger with NIST calibration certificate, an extended range thermal shield, OM-CP-IFC200 interface cable, FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols
OM-CP-AVS150-5-CERT
Includes (5) OM-CP-HITEMP-150 data loggers with NIST calibration certificates, (5) extended range thermal shields, OM-CP-IFC200 interface cable, FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols
OM-CP-AVS150-5-CERT采集 美國omega
OM-CP-AVS150-CERT數據采集器 美國omega
OM-CP-AVS150-5-CERT數據采集器 美國omega
OM-CP-AVS150-CERT采集器 美國omega
OM-CP-AVS150-5-CERT采集器 美國omega
OM-CP-AVS150-CERT采集 美國omega
美國omega OM-CP-AVS150-CERT數據采集器
美國omega OM-CP-AVS150-5-CERT數據采集器
美國omega OM-CP-AVS150-CERT采集器
美國omega OM-CP-AVS150-5-CERT采集器
美國omega OM-CP-AVS150-CERT采集
美國omega OM-CP-AVS150-5-CERT采集
衍生閱讀:大,開門后部分區域的空氣形成蝸流,風速增大到約手術間原風速的4倍,此時物體表面附著物迅速飄浮于空氣中。根據美國CDC的調查表明手術室空氣中浮游菌數在700-800cfu/m3時就有經空氣感染的危險。從結果可見,手術時鋪單至鋪單后2小時空氣污染zui嚴重,此時正是手術階段。由于受重力作用,室內飄塵可直接沉降到手術創面,或操作者的手或手術器械上,因此加強控制此期的空氣污染對預防術后切口感染是致關重要的。這些要求衛生防疫部門通過自己的監測確認各醫院手術室的達標情況,記錄儀是一種很好的方法,減少了人員浪費,并使執法的公正性得到保證。 管路維護:管路里的濕氣會促進微生物生長,管道上發霉就是這樣形成的。這不但影響空氣流動,還會滋生大量細菌。這些遭到污染的區域對健康構成威脅,并zui終導致室內空氣質量(IAQ,Indoor Air Quality)惡化。 血庫儲存。法國的一家醫院就是使用數據記錄儀監測冷庫的血樣儲存.醫院血樣部門負責人說血庫
相關產品:
OMB-DAQ-2416數據記錄儀 美國omega


您的位置: